VM
Download here the NEW User Manual for the Vacuumjet System!
80°C (176°F).
When we don’t achieve depression it means that the cavity isn’t hermetically closed. This can happen due to tools that have a lot of lifters and/or cam slides where closing the cavity hermetically is difficult. When this happens a solution is to apply more than one VACUUM JET (VJ), this will increase the suction power. In order to have vacuum in a cavity we need to be able to take more air out than is coming in, this can be achieved when multiple VJ’s are applied in order to compensate the air that is coming in.
No, the unit makes vacuum through a venturing principal. The biggest advantage of this concept is that no auxiliary machines are needed, this is why this solution is very cost effective.
Simply reset the unit to zero point setting, or by desconnecting and reconnecting.