Vacuum Control

Vakummetre
Referans:
VM503032
Opsiyon
  • Kontrol
Açıklama
This unit allows to control the vacuum level in the cavity.
Should be combined with the VJ or VG.
Read moreShow less
Ürün Detayları
VM503032
Questions(FAQs)
    Where can I find a Vacuumjet System user manual?
    Download here the NEW User Manual for the Vacuumjet System!

    What is the maximum working temperature?
    80°C (176°F).

    What to do when I don’t achieve depression in my cavity?
    When we don’t achieve depression it means that the cavity isn’t hermetically closed. This can happen due to tools that have a lot of lifters and/or cam slides where closing the cavity hermetically is difficult. When this happens a solution is to apply more than one VACUUM JET (VJ), this will increase the suction power. In order to have vacuum in a cavity we need to be able to take more air out than is coming in, this can be achieved when multiple VJ’s are applied in order to compensate the air that is coming in.

    Is an external pump needed to make the Vacuum Unit work?
    No, the unit makes vacuum through a venturing principal. The biggest advantage of this concept is that no auxiliary machines are needed, this is why this solution is very cost effective.

    What should I do if the display does not show 000 when the cycle has finished?
    Simply reset the unit to zero point setting, or by desconnecting and reconnecting.

Video

Kurulum videosu

Açıklama videosu

Siz de beğenebilirsiniz
Ürün yok

HANGİ DOUBLE RACK SISTEMI İHTİYACIM VAR?

Projeniz için en iyi seçeneği arayın

Close
Click for more products.
No products were found.

Menu